MindEar (Tinnibot) chatbot CBT: pilot RCT

Record details

What this research found

TFI decreased 11.2 (chatbot-only) vs 20.0 (hybrid) post-treatment; clinically significant improvement 42% vs 64%, converging to 64% in both arms at 16 weeks; between-group differences not significant.

Pilot only: no untreated arm, small N, baseline imbalance, and no trial registration stated. First author co-founded the developer (Odio Tech) — sponsor-linked. Not indexed in PubMed at extraction time.

Limitations and conflicts of interest

N=30 pilot; no registration stated; no untreated control.

Funding / conflicts: Company-linked (first author co-founded the developer).

Primary sources

Used as evidence for

This is an original summary from the Tinnitus Evidence verified database, checked against the primary source — not a reproduction of the publisher's abstract.